Rockefeller,Mitchell,Reynolds,Hutchinson,Zoology,Erman,Mandel,Oriental,Pres.HomeΒ
Chicago Building ID: 252054
Building Info
- Square Footage
- 58,574 sqftLower than 92% of all buildings1/2 median139,707 sqft0.6x median Worship Facility91,800 sqft
- Built
- 1928
- Primary Property Type
- Worship Facility
- Community Area
- Hyde Park
- Chicago Energy Rating
- 1.0 / 4
- Energy Star Score
- 1 / 100
- Owner
Emissions & Energy Information for 2022
- Greenhouse Gas Intensity
- 12.9 kg CO2e / sqft#2 Highest of Worship Facilities π¨Higher than 93% of all buildings2.0x median6.4 kg CO2e / sqft2.2x median Worship Facility5.9 kg CO2e / sqft
- Total Greenhouse Gas Emissions
- 753.3 tons CO2eLower than 57% of all buildings0.9x median885.8 tons CO2e1.0x median Worship Facility785.5 tons CO2e
Years Reported 8/8 A
2015
2016
2017
2018
2019
2020
2021
2022
Energy Breakdown
- Natural Gas Use
- 0 kBtu#1 Lowest of Worship Facilities πLower than 97% of all buildingsMedian Chicago Building5,818,399.6 kBtuMedian Worship Facility6,137,653 kBtuThis Building Uses District Heating β
Although this building didn't burn any natural gas on site, it's connected to a district heating system, a centralized system for heating multiple buildings. District heating systems can be fully electric, but in Chicago most district heating systems are natural gas powered, meaning this building was most likely still heated with natural gas.
- Electricity Use
- 2,380,547.6 kBtuEst. Electric Bill: $100,000 for 2022**Lower than 66% of all buildings0.6x median3,796,376.7 kBtu1.0x median Worship Facility2,380,547.6 kBtu
- District Steam Use
- 6,623,440.5 kBtu
Most buildings don't use district steam, so we don't currently have comparison data.
Energy Mix
Total Energy Use: 9,003,988 kBTU
View Extra Technical Info
- Source Energy Usage Intensity
- 249.8 kBtu / sqft#2 Highest of Worship Facilities π¨Higher than 92% of all buildings1.9x median132.2 kBtu / sqft2.0x median Worship Facility122.3 kBtu / sqft
- Site Energy Usage Intensity
- 153.7 kBtu / sqft#2 Highest of Worship Facilities π¨Higher than 93% of all buildings2.0x median78.4 kBtu / sqft2.3x median Worship Facility66.4 kBtu / sqft
Full Historical Data Table
Year | Floor Area sqft |
Chicago Energy Rating |
Energy Star Score | GHG Intensity kg CO2e / sqft | GHG Emissions metric tons CO2e | Source EUI kBTU / sqft | Electricity Use kBTU | Natural Gas Use kBTU | District Steam Use kBTU |
---|---|---|---|---|---|---|---|---|---|
2015 | 351,843 | - | - | 16.7 | 5,867 | 277.0 | 18,291,128 | 2,739,450 | 29,788,389 |
2016 | 341,130 | - | - | 15.9 | 5,410.9 | 277.7 | 17,599,293 | 1,625,340 | 30,259,041 |
2017 | 341,130 | - | - | 15.9 | 5,430.9 | 278.8 | 17,579,033 | 1,891,000 | 27,248,273 |
2018 | 341,130 | 1.0 | - | 15.1 | 5,150.4 | 262.7 | 17,242,408 | 1,992,790 | 29,366,023 |
2019 | 341,130 | 1.0 | - | 14.3 | 4,865.6 | 256.6 | 16,076,559 | 2,233,370 | 27,372,008 |
2020 | 103,012 | 1.0 | - | 15.8 | 1,627.3 | 281.8 | 4,468,194 | - | 8,115,450 |
2021 | 103,012 | 1.0 | - | 14.1 | 1,449.5 | 262.0 | 4,483,125 | 0 | 8,117,098 |
2022 | 58,574 | 1.0 | 1 | 12.9 | 753.3 | 249.8 | 2,380,547 | 0 | 6,623,440 |
* Note on Rankings: Rankings and medians are among included buildings, which are those who reported under the Chicago Energy Benchmarking Ordinance for the year 2022, which only applies to buildings over 50,000 square feet.
** Note on Bill Estimates: Estimates for gas and electric bills are based on average electric and gas retail prices for Chicago in 2021 and are rounded. We expect large buildings would negotiate lower rates with utilities, but these estimates serve as an upper bound of cost and help understand the volume of energy a building is used by comparing it to your own energy bills! See our Chicago Gas & Electric Costs Source for the original statistics.
Data Source: Chicago Energy Benchmarking Data